Service Provider of a wide range of services which include ahu & air washer unit and treated fresh air unit.
AHU & Air Washer Unit
  • AHU & Air Washer Unit
  • AHU & Air Washer Unit
  • AHU & Air Washer Unit

AHU & Air Washer Unit

Product Price: Rs 2.5 Lakh / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Details:
TypeDouble Skin
Usage/ApplicationIndustrial
ApplicationIndustrial/Commercial
Capacity2000 to 50000cfm
BrandATR
Materialgi and aluminium
Installation TypeFloor Mounted
SizeLarge
Floor MountedYes
Automatic GradeYes
A primary cooling coil system is incorporated into the AHU to recycle the condensate water in order to achieve energy savings. The warm outside fresh air is drawn through the primary cooling coil to recover the latent heat of condensate water. The large temperature gradient between the warm fresh air and condensate water enlarges the amount of energy recovered. This system is well applicable to primary AHU which serves primary air to the air-conditioning system. The cost of installing the device is negligible but in returning long term saving. Furthermore, the de-cooled condensate water can be drained off through non-insulated drain pipe. The idea generation is discussed in the introduction. 

Additional Information:

  • Item Code: 8414
  • Production Capacity: 50000cfm per day
  • Delivery Time: 4 TO 5 Days
  • Packaging Details: pvc rapped
Get Best QuoteRequest A Callback
Treated Fresh Air Unit
  • Treated Fresh Air Unit
  • Treated Fresh Air Unit
  • Treated Fresh Air Unit

Treated Fresh Air Unit

Product Price: Rs 25,000 / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Details:
TypeDouble Skin
BrandATR COOL
Capacity400 cfm to 25K cfm
Usage/Applicationhospitals. factories, offices, basement
Installation TypeAt Site
SizeLarge, Medium, Small
MaterialGI sheet cooper coil ss drain tray
Airflow400cfm to 25000cfm
Corrosion Resistantwater proof and corrosion resistant
Dimensionas per capacity
Featurewith 6 row deep coil
Outletas per ambient temp
Phasethree
Power Consumptionminimum 500Watt
Voltage410 VAC
Water Capacity10 GPM
Automatic GradeYes
A primary cooling coil system is incorporated into the TFA to condensate water in order to achieve energy savings. The warm outside fresh air is drawn through the primary cooling coil to recover the latent heat of condensate water. The large temperature gradient between the warm fresh air and condensate water enlarges the amount of energy recovered. This system is well applicable to primary TFA which serves primary air to the air-conditioning system. The cost of installing the device is negligible but in returning long term saving. Furthermore, the de-cooled condensate water can be drained off through non-insulated drain pipe. The idea generation is discussed in the introduction. 

Additional Information:

  • Item Code: 8814
  • Production Capacity: 10
  • Delivery Time: 7 days
Get Best QuoteRequest A Callback